天然产物研究与开发 ›› 2014, Vol. 26 ›› Issue (12): 1926-1929.

• 研究论文 • 上一篇    下一篇

微波消解ICP-MS法测定凤丹花中多种可溶性元素

李梅青*,孔祥淋,杜晓妹,孙强,吴悠   

  1. 安徽农业大学茶与食品科技学院,合肥 230036
  • 出版日期:2014-12-31 发布日期:2015-01-09

Determination of Soluble Elements in Paeonia ostii Flowers by ICP-MS with Microwave Digestion

LI Mei-qing*, KONG Xiang-lin, DU Xiao-mei, SUN Qiang, WU You   

  1. School of Tea and Food Science,Anhui Agricultural University,Hefei 230036,China
  • Online:2014-12-31 Published:2015-01-09

摘要: 采用微波消解电感耦合等离子体质谱(ICP-MS)法测定两种凤丹花(凤丹白、凤丹粉)中8种可溶性元素Cr、As、Se、Cd、Sb、Ba、Hg、Pb的含量。结果表明:测定的两种凤丹花样品中,凤丹白中8种可溶性元素含量均高于凤丹粉中的含量;将检测结果与《食品中污染物限量》(GB 2762-2005)比较可知,两种凤丹花的各项指标普遍高于水果和叶菜类标准限量;与茶叶的唯一有害元素Pb的标准限量相比,两种凤丹花Pb含量远低于茶叶限量标准。本研究结果表明,凤丹花可作为茶品用于饮用,但作为食品食用有一定的限制。本方法的加标回收率范围为92.25%~106.75%;相对标准偏差RSD为1.3%~4.8%,表明试验精确度高,数值可靠。

关键词: 凤丹, 微波消解, 电感耦合等离子体质谱, 可溶性元素

Abstract: A method based on microwave digestion and inductively coupled plasma-mass spectrometry(ICP-MS)detection was established for the determination of eight soluble elements,including Cr,As,Se,Cd,Sb,Ba,Hg,Pb,in Paeonia ostii White and Paeonia ostii Pink.The samples were dissolved in HNO3 by microwave digestion,then the above 8 elements were simultaneously detected by ICP-MS.The results showed that the contents of eight soluble elements in P.ostii White were higher than that of P.ostii Pink.The results were evaluated by analyzing the Maximum Levels of Contaminants in Foods(GB2762-2005),the indicators of two P.ostii flowers were generally higher than the limits of fruits and the leafy vegetables;compared with the standard limits of the only harmful element Pb in tea,the contents of Pb in two P.ostii flowers were much lower than the limits of tea.The results of this study showed that P.ostii flowers can be used as a tea for drinking,but it has certain limitations being a kind of food.The recovery rates of the studied elements were in the range of 92.25%-106.75%,and the relative standard deviations(RSDs)of the method were in the range of 1.3%~4.8%.The experimental results showed that the developed ICP-MS method was precise and reliable.

Key words: Paeonia ostii, microwave digestion, inductively coupled plasma-mass spectrometry, soluble element

中图分类号: 

TS207.5